LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> AJ71E71N-B2 User's Manual MITSUBISHI AJ71E71N-B2 Manual

AJ71E71N-B2 User's Manual MITSUBISHI AJ71E71N-B2 Manual

Product model: AJ71E71N-B2
Name: Ethernet Interface Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 14.88MB
Self service (IN, OUT): SI optical cable.
Other aspects (IN, OUT): SI optical cable.
Data link anomaly Bureau bypass.
Inter agency extension. Series Name: A950GOT.
Size: 6 inches.
Resolution: 320 * 240.
Display device: STN color display.
Display color: 8 color.
Power supply: DC24V.
Built in RS-422 communication interface
Memory card: 3M MITSUBISHI AJ71E71N-B2 Manual.
Some mechanical industries, such as machine tools, textile machinery, electronic equipment and other industries,
In the country has been developed for decades of history, relatively speaking, is relatively mature industry, in the long run,
These industries also exist the needs of equipment upgrades AJ71E71N-B2
In this upgrading process, there will be some small, has been using relatively low-end products manufacturers are eliminated,
But there are also a lot of enterprises in the process of equipment renewal,
Re positioning the needs to find those that can meet their development plans,
Equipment suppliers to help them improve their productivity MITSUBISHI AJ71E71N-B2 Manual. Multi axis positioning controller.
Coaxial data communication line function.
Program capacity: Max 60K step.
Input / output points: 1920 points MITSUBISHI AJ71E71N-B2 Manual.
PLC commonly used in memory are EPROM, EEPROM and with lithium battery powered RAM.
General micro and small PLC storage capacity is fixed, between 1~2KB.
How much memory is occupied by a user application is related to many factors,
Such as I/O points, control requirements, computing processing, program structure, etc..
So it can only be roughly estimated before the program is designed. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DAC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Optical data communication line.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure off how much the user application can store the number of indicators AJ71E71N-B2 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AJ71E71N-B2 User's Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Ethernet module
AJ71E71-S3
MITSUBISHI Ethernet module AJ71E71-S3
10BASE5/10BASE2 Control layer /MELSECNET/10
MITSUBISHI
Network module
AJ71E71N-B2
MITSUBISHI Network module AJ71E71N-B2
10BASE2. When communicating in the PLC networ
MITSUBISHI
Ethernet module
AJ71E71N-T
MITSUBISHI Ethernet module AJ71E71N-T
10BASE-T Control layer /MELSECNET/10 H is t
MITSUBISHI
Ethernet module
A1SJ71QE71N-B2
MITSUBISHI Ethernet module A1SJ71QE71N-B2
10BASE2. Q mode. MITSUBISHI PLC is the main p