LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> FX3G-24MT/DSS USER'S MANUAL MITSUBISHI FX3G-24MT/DSS Hardware Edition Manual

FX3G-24MT/DSS USER'S MANUAL MITSUBISHI FX3G-24MT/DSS Hardware Edition Manual

Product model: FX3G-24MT/DSS
Name: PLC
Brand: MITSUBISHI
Sort: Hardware Edition USER'S MANUAL
File language: English
File size: 11.63MB
Application: a write device (with a built-in flash memory) that is not required to use a similar ROM writer,
GOT can be carried out between the fast and simple picture data transmission.
Application Series: F940WGOT, F940GOT. Extended power supply for CPU module with built-in power supply.
Bus conversion module is required when using MITSUBISHI FX3G-24MT/DSS Manual. Maximum can be connected to 2 sets FX3G-24MT/DSS Input signal: thermocouple type K or type J.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Thermocouple type temperature sensor input module.
Thermocouple type (K type, J type) temperature sensor input module.
4 channels can be entered.
Unit can be set to Celsius or fahrenheit MITSUBISHI FX3G-24MT/DSS Manual.
Resolution is K type 0.4 degree, J type 0.3 degree of high precision. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 500kw.
SLD converter rated current: 1094A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON MITSUBISHI FX3G-24MT/DSS Manual.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 37KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly uused in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3G-24MT/DSS USER'S MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3G-24MT/DSS USER'S MANUAL. "
Related products
MITSUBISHI
PLC
FX3U-32MT/DSS
MITSUBISHI PLC FX3U-32MT/DSS
Max input / output points: 32 points. Power s
MITSUBISHI
PLC
FX3UC-32MT/DSS
MITSUBISHI PLC FX3UC-32MT/DSS
Input and output points: 32 points. Input poi
MITSUBISHI
Function expansion board
FX3G-2EYT-BD
MITSUBISHI Function expansion board FX3G-2EYT-BD
Output points: 2 points. Output form: transis
MITSUBISHI
PLC
FX3G-40MT/DSS
MITSUBISHI PLC FX3G-40MT/DSS
Input and output points: 40 points. Power sup