MITSUBISHI AJ35PJ-8T3 User's Manual AJ35PJ-8T3 Manual

Product model: AJ35PJ-8T3
Name: I/O MODULE
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 6.99MB
Program memory capacity 14K.
Input and output points to the maximum 512 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage AJ35PJ-8T3 User's Manual AJ35PJ-8T3 Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AJ35PJ-8T3 User's Manual.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. A65B/A68B/A55B/A58B connection cable.
Length: 400mm. DC input points: 32 points AJ35PJ-8T3 User's Manual.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
Positive pole sharing.
16 point /1 a public side.
Output points: 24 points.
Output voltage and current: DC12/24V, 0.5A/1 point, 3.2A/1 common end.
Response time: 2ms.
8 point /1 a public end, 4 point /1 a public end.
Output form: transistor output, leakage type.
36 point terminal table * 2.
Number of stations: 8 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong AJ35PJ-8T3 Manual .
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness AJ35PJ-8T3 Manual .
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
DC input / transistor output module
AJ35PTF-56DT
MITSUBISHI DC input / transistor output module AJ35PTF-56DT
DC input points: 32 points. Input voltage and
MITSUBISHI
AC100V input module
AJ35PTF-32A
MITSUBISHI AC100V input module AJ35PTF-32A
AC input points: 32 points. Input voltage and
MITSUBISHI
Melsecnet module
AJ35PP-CNV
MITSUBISHI Melsecnet module AJ35PP-CNV
MELSECNET/MINI -S3 data link system, A2C sy
MITSUBISHI
DC input / silicon controlled output module
AJ35PTF-56DS
MITSUBISHI DC input / silicon controlled output module AJ35PTF-56DS
DC input points: 32 points. Input voltage and