Input points: 16 points.
Voltage: DC100/110/125V.
Current: 2mA.
Response time: 20ms.
8 points / a common end.
Positive / negative sharing.
20 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation AY42 Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear
AY42
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference AY42 Manual. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AY42 Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program MITSUBISHI I/O Module Manual.
The length of the scan cycle is determined by the three MITSUBISHI I/O Module Manual.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay. RS-232C connection (QCPU direct connection, computer connection, micro computer connection) MITSUBISHI I/O Module Manual.
No clock function.
Applicable models: A985 (-V) /975/970/960GOT AY42 User's Manual. Available network: 10BASE2.
Max / total distance: 185/925m.
A1SJ71E71 is a compact Ethernet interface module,
Used to hang PLC series ANS to ethernet.
There are two kinds of hanging network modules: A11SJ71E71-B2-S3 and A1SJ71E71-B5-S3 respectively corresponding to 10BASE2 and 10BASE5,
So that the vast majority of installed cable can continue to use AY42 Manual.