MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 7.5kw.
SLD converter rated current: 49A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation FX2N-422-BD USER'S MANUAL.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station
FX2N-422-BD
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced FX2N-422-BD USER'S MANUAL. Max input / output points: 128 points.
Supply voltage: 100 - 240VAC.
Input points: 64 points.
Output points: 64 points.
Output type: Transistor (source).
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module FX2N-422-BD USER'S MANUAL.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Max input / output points: 64 points.
Supply voltage: 100 - 240VAC.
Input points: 32 points.
Output points: 32 points.
Output type: relay.
Power consumption: 60VA.
Weight (kg):1.20.
Size (WxHxD) mm:285x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection,, using a eight digit password to protect your program FX2N-422-BD Manual.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FX2N-422-BD Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).