Name: DC Power Supply Unit.
Power supply voltage: 24 VDC.
Output capacity: 5 VDC output capacity, 5.3A;
26 VDC output capacity, 1.3A;
Total, 40W.
Options: 24 V DC service power supply, No;
RUN output, No.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CJ2M-CPU11 USER'S MANUAL. Specifications: Optical ring(GI cable).Product name: CS1 CPU Backplane
CJ2M-CPU11
Specifications: For both CS/C200H-series Units,
2 slots(Note:Expansion Racks,
cannot be connected).
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes CJ2M-CPU11 USER'S MANUAL.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Product name: N@@-type CPU Units with 40 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 24; Outputs, 16;
Output type: Relay CJ2M-CPU11 USER'S MANUAL.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.21A; 24 V,0.09A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. CVM1-CL Accessory MODULE, CONTROLLER LINK, 62.5FIB CVM1-CLK52.Name: SYSMAC LINK Module.
Model: C200HW-SLK24.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.Model: C200H-PS221.
Supply voltage: 120/240VAC.Model : C500-PS221.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 7 A, 5VDC.Connects Power Supply Adapter and SYSMAC NET Link Unit.
For 1 Unit.Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ2M-CPU11 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ2M-CPU11 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.