Specification: Resin, different end diameter.
Shaft interior (tolerance *) exterior dia: 6 dia. 10 dia. (Height: 8), 22 dia.
Couplings.
Coupling Materials and Characteristics.
OMRON provides two types of couplings for different.
application conditions: Resin and metal.
Select the best type for the application E5CN-HV2BFD MANUAL. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V)
E5CN-HV2BFD
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: - E5CN-HV2BFD MANUAL.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5CN-HV2BFD MANUAL.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer OMRON Temperature Controller MANUAL. 4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultElement type: K (CA) OMRON Temperature Controller MANUAL.
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 12 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors OMRON Temperature Controller MANUAL.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 22 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperatture Sensors E5CN-HV2BFD USER'S MANUAL.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HV2BFD MANUAL.