Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 E5CN-Q2LD MANUAL.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485
E5CN-Q2LD
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices E5CN-Q2LD MANUAL.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements E5CN-Q2LD MANUAL.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method OMRON Temperature Controller MANUAL.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit OMRON Temperature Controller MANUAL. The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling OMRON Temperature Controller MANUAL.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5CN-Q2LD User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-Q2LD MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.