Ontology: basic.
Size: 48 x 96mm.
Type: basic type (1 input)
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line E5CN-R2HBL MANUAL
E5CN-R2HBL
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation.
1 digital controller can be multi point control / series control / proportion control E5CN-R2HBL MANUAL.
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output E5CN-R2HBL MANUAL.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2 OMRON Temperature Controller MANUAL.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON Temperature Controller MANUAL.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON Temperature Controller MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control outputt: Relay E5CN-R2HBL USER'S MANUAL.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching.
A sensor is provided to enable immediate application.
Sockets wiith finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used E5CN-R2HBL MANUAL.
Simple operation and settings. Even simpler with digital models.