SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Controller network (control station / common station) / remote I/O network (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station MITSUBISHI CPU Strctured Programming Manual Q172CPUN-T
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network MITSUBISHI CPU Strctured Programming Manual.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Three-phase 3 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information MITSUBISHI CPU Strctured Programming Manual.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q172CPUN-T Strctured Programming Manual.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm Q172CPUN-T Strctured Programming Manual.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment Q172CPUN-T Strctured Programming Manual.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.Connect to read and write 1Ch.
ID system interface module.
ID controller M-688-001/002 BIS can be installed directly to the Q series of substrates,
Control module for reading and writing ID tag data through a programmable logic controller.
The ladder diagram of M-688-002 BIS is compatible with QD35ID1/2 Q172CPUN-T Manual.
2 antennas can be connected, and the parallel processing of the 2 channels can be simultaneously carried out.
Can use all ID tags in the M BIS series.
ID series /BIS system is an industriaal automation ID system which can use the electromagnetic combination method to read and write data MITSUBISHI CPU Strctured Programming Manual.
ID tag has a variety of sizes and storage capacity.
Related products
MITSUBISHI
Motion CPU module
Q173CPUN-T
MITSUBISHI Motion CPU module Q173CPUN-T
Control axis: maximum 32 axes. Teaching runni
MITSUBISHI
Sports CPU module (old model)
Q172CPU
MITSUBISHI Sports CPU module (old model) Q172CPU
Control axis: maximum 32 axes. Compact size a
MITSUBISHI
Motion CPU module
Q172CPUN-T
MITSUBISHI Motion CPU module Q172CPUN-T
Control axis: maximum 8 axes. Teaching runnin
MITSUBISHI
Motion CPU module
Q172CPUN
MITSUBISHI Motion CPU module Q172CPUN
Control axis: maximum 8 axes. Greater flexii