Home >> Download >> MITSUBISHI >> Manual Download >> QJ71PB93D User's Manual MITSUBISHI QJ71PB93D Manual

QJ71PB93D User's Manual MITSUBISHI QJ71PB93D Manual

Product model: QJ71PB93D
Name: PROFIBUS-DP Slave Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 2.33MB
Adapter for Q2MEM memory card with standard PCMCIA interface.Adapter for mounting DIN guide rail.
For Q35B-E, Q65B, Q00JCPU.8 slots.
Requires 1 power modules.
Used to install the old section of the large A series PLC module.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI QJ71PB93D Manual QJ71PB93D
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process MITSUBISHI QJ71PB93D Manual. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program MITSUBISHI QJ71PB93D Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures QJ71PB93D User's Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down QJ71PB93D User's Manual.
Related products
MITSUBISHI
Coaxial bus module
QJ71BR11
MITSUBISHI Coaxial bus module QJ71BR11
3C-2V/5C-2V coaxial cale. Single us. PLC to
MITSUBISHI
FL-net module
QJ71FL71-B2-F01
MITSUBISHI FL-net module QJ71FL71-B2-F01
FL-net OPCN-2 Ver.2.00 interface. 10BASE2 u
MITSUBISHI
Ethernet module
QJ71E71-100
MITSUBISHI Ethernet module QJ71E71-100
10BASE-T/100BASE-TX. Ethernet interface modul