The input and output module installation number: 8.
Can install module: iQ-R MELSEC series module.
DIN guide rail mounting adapter type: R6DIN1.
Size (H) * (32.5mm) * (W) * (D): * 328mm * 101mm.
Substrate module for mounting various modules of iQ-R MELSEC series.
CPU module could not be installed on the extended substrate module R312B PDF catalog . "The input and output module installation number: 12
R312B
Can install module: MELSEC-Q series module.
DIN guide rail mounting adapter type: Q6DIN1.
Size (H) * (44.1mm) * (W) * (D): * 439mm * 98mm.
Substrate module for mounting various modules of MELSEC-Q series.
Extended use of Q series expansion substrates in the following extensions. "Analog input channel number: 4CH R312B PDF catalog .
Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/W26Re.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing R312B PDF catalog .
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection: 18 point screw terminal two.
Temperature tracking function can be monitored in real time MITSUBISHI R312B PDF datasheet.
Using Works3 GX in the temperature function, can be real-time tracking temperature, in the confirmation of the temperature waveform and parameter adjustment MITSUBISHI R312B PDF datasheet.
In addition, the temperature can be saved as a CSV file after the export, the use of a variety of purposes.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points MITSUBISHI R312B PDF datasheet.
Heating function between modules.
Peak current suppression function between modules.
Temperature risingg function between modules
By cooperating with the time of arrival of a number of loops, the average temperature is controlled R312B datasheet.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomeenon of thermal expansion R312B PDF catalog . Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy.