Sensing method: Diffuse-reflective.
Appearance: Vertical.
Connection method: Pre-wired Connector (M12).
Sensing distance: 2m.
Water- and Oil-resistant.
Photoelectric Sensor with.
Metal Housing Used for Long.
range Sensing.
Excellent resistance against the water and oil.
Easy application in locations with oil mist OMRON E5CN-HR2H01D-FLK MANUAL.
Long-range sensing up to 30 m with Through-beam models
E5CN-HR2H01D-FLK
Shock resistance rated at 1,000m/s2.
Product lineup includes metal M12 pre-wired connector models.
NPN/PNP selector switch output. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling OMRON E5CN-HR2H01D-FLK MANUAL.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance OMRON E5CN-HR2H01D-FLK MANUAL.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cablle (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5CN-HR2H01D-FLK User's Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5CN-HR2H01D-FLK User's Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).