Product model: E5CN-HTC2D
Name: Temperature Controller
Brand: OMRON
Sort: User's Manual
File language: English
File size: 1.17MB
Control output 1: Linear current output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: --.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation E5CN-HTC2D.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications E5CN-HTC2D
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Size: 48 x 48mm.
Body: terminal type E5CN-HTC2D.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products E5CN-HTC2D.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultTerminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.

Temperature Sensors E5CN-HTC2D.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HTC2D.
Related products
OMRON
Basic-type Digital Temperature Controller
E5CN-QTDU
OMRON Basic-type Digital Temperature Controller E5CN-QTDU
Size: 1/16 DIN. Case color: Black. Power su
OMRON
Programmed temperature controller
E5CN-HTQ2H03-FLK
OMRON Programmed temperature controller E5CN-HTQ2H03-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Foundation type temperature controller
E5CN-CTD
OMRON Foundation type temperature controller E5CN-CTD
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-Q2HH03T-FLK
OMRON Foundation type temperature controller E5CN-Q2HH03T-FLK
The main ody: terminal type, temperature inp