Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-RQ3BT-N.
Ideal for the thermal input devices of Temperature Controllers
E5EN-RQ3BT-N
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Amplifier Unit.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head E5EN-RQ3BT-N.
Heat-resistance model available for application between.
-10 and 200°C. Programmable Controllers Join the Series!
Program up to 256 segments and take,
advantage of the high cost performance,
of the new LCD that improves both the,
field of view and contrast.
Set up to 8 programmed patterns with up to 32 segments (steps) each.
High-resolution display with 5 digits/0.01°C display in a compact,
Controller (48 x 48 mm) E5EN-RQ3BT-N.
High-speed sampling cycle of 60 ms.
High Accuracy.
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/RESET, and alarms) and the PV or SV.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo version 4.3).
Program settings can be managed.
Preventive maintenance for relays in the Temperature Controller,
using a Control Output ON/OFF Counter. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to ccheck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-RQ3BT-N.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5EN-RQ3BT-N.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.