Sensing method: Through-beam type.
Sensing distance: 300 mm.
Output type: NPN output.
Output configuration: Light-ON.
Cable length: 2 m.
Cable length from emitter to amplifier: 0.5 m.
Compact, Thin-profile.
Photomicrosensor with special amplifier.
Slim amplifier (50 × 7.5 × 12 mm) can be handled like a cable E5AN-HAA2HBM-W-500.
Provided with two operation indicators, enabling monitoring from the,
amplifier housing and sensor head
E5AN-HAA2HBM-W-500
Simple wiring with a 3-conductor cable.
Wide operating voltage range: 12 to 24 VDC. Small, easy to use.
Detection mode: on the radio.
Shape: vertical type.
Connection mode: lead wire.
Detection distance: 2 meters of red light.
Output mode: PNP output. Size: 96 x 96mm.
Ontology: terminal type, analog input type E5AN-HAA2HBM-W-500.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output) E5AN-HAA2HBM-W-500.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thhe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AN-HAA2HBM-W-500.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AN-HAA2HBM-W-500.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.