Continuation of the E6B2 high cost, value also have more choice.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference.
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure E5CN-HR2H03D-FLK
E5CN-HR2H03D-FLK
E6B2 complementary output will be issued over the same period.
Connection length to reach a full 30m!
Resolution (pulse / rotation):10~3600P/R.
Power supply voltage: DC12 ~ 24V
Consumption current: 100mA below.
Output state: complementary output.
Maximum response frequency: 100kHz.
Output phase difference: A phase, B phase difference 90 plus or minus 45 E5CN-HR2H03D-FLK.
Starting torque: M / 10mN below (at room temperature).
Maximum allowable speed: 6000r/min.
Axial force: radial...... 80N, axial...... 50N. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling E5CN-HR2H03D-FLK.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Type: plug - in.
Size: 48 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 2 points.
Communication: -.
Heater break: 1.
Event input: 2 points.
Power supply voltage: AC/DC24V.
Using large font PV display (white), improve visibility.
Selection, setting and operation more simple and more group of input / output,
Functional performance is stronger, the function is more perfect and more extensive range of applications E5CN-HR2H03D-FLK.
E5EC-800 white LCD-PV display height is about 18mm,
The E5AC-800 white LCD-PV display height is about 25mm improved visibility.
The main body is short, the thickness is only 60mm E5CN-HR2H03D-FLK.
50ms high speed sampling period.
A new type of proportional control allows you to control the valve.