File size: 6.14MB
High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: there.
Shape: non shield, M30.
Detection distance: 20mm.
Action mode: NC. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V) E5CN-R2HH03LD-FLK.
Shell color: black.
Control output: linear voltage output E5CN-R2HH03LD-FLK
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products E5CN-R2HH03LD-FLK.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5CN-R2HH03LD-FLK.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSize: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: relay.
Input: thermocouple.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed.
Can use heating or heating / cooling control.
Event entry allows multiple SP options and run / stop functions. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperaature Sensors E5CN-R2HH03LD-FLK.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-R2HH03LD-FLK.
Related products
OMRON
Foundation type temperature controller
E5CN-R2H03TD-FLK
OMRON Foundation type temperature controller E5CN-R2H03TD-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-R2HH03T-FLK
OMRON Foundation type temperature controller E5CN-R2HH03T-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-CQ203LD-FLK
OMRON Foundation type temperature controller E5CN-CQ203LD-FLK
Ontology: terminal type, analog input type. T
OMRON
Foundation type temperature controller
E5CN-R2HH03TD-FLK
OMRON Foundation type temperature controller E5CN-R2HH03TD-FLK
The main ody: terminal type, temperature inp