Power supply voltage: DC.
Sensing method: Through-beam (Emitter + Receiver).
Sensing distance: 5 m.
Output configu ration: NPN.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models) E5EN-QY3T-N.
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2
E5EN-QY3T-N5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup E5EN-QY3T-N. )
Models with infrared LEDs are also available. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5EN-QY3T-N.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(autommatic / manual, RUN/STOP, alarm), interactive display PV/SV E5EN-QY3T-N.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-QY3T-N.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.