Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: DC 24V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G9SX-AD322-T150-RT .
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals
G9SX-AD322-T150-RT
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires G9SX-AD322-T150-RT .
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Cable /G79-Y_C with loose wire connecting terminal.
L size: 3000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable G9SX-AD322-T150-RT . Main contacts: 3PST-NO.
OFF-delay contacts: DPST-NO.
Auxiliary contact: SPST-NC.
Number of input channels: 1 channel or 2 channels possible.
OFF-delay time: 15 s.
Rated voltage: 24 VAC/VDC; 100 to 240 VAC.
The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (PLe/Safety Category 4).
Both DIN track mounting and screw mounting are possible. Contact form: DPDT.
Classification: Standard model.
Plug-in terminals.
Magnetic Latching Version of G2A Ideal for.
Sequence Control.
Double-winding latch system with continuous rating.
Terminals pulled from the respective junctions betweeen the,
built-in diodes and set and reset coils allow the built-in diodes to,
be externally connected for coil surge absorption G9SX-AD322-T150-RT USER'S MANUAL.
Excellent vibration/shock resistance with minimal secular,
decrease in latching poower G9SX-AD322-T150-RT USER'S MANUAL.
Easy monitoring of ON/OFF operation due to the built-in,
operation indicator mechanism.
Same outline dimensions as the standard models of G2A.