Timer input: No-voltage input.
Display: 7-segment LCD.
Time range: 999999.9h ←→ 3999d23.9h(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC) H5S-YB4-X Manual.
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000
H5S-YB4-X0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000.0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1 H5S-YB4-X Manual. Supply voltage: 12 to 24 VDC.
8-digit total counter: Black.
DIN 72 x 36-mm Total Counter/Time Counter with.
Easy-to-read Displays and Water and Oil.
Resistance Equivalent to IP66.
Large, easy-to-read displays: 15-mm-high characters for 6-digit mod,
els; 12-mm-high characters for 8-digit models.
High-visibility, negative transmissive LCD display with built-in red LED,
backlight at low power consumption H5S-YB4-X Manual.
IP66 with oil resistance and NEMA4 are achieved by unifying the front,
with the casing case and using oil-resistant materials and parts.
Compact (66 mm) body.
Switch 6-digit models between total counter and time counter operation,
Just change a switch setting for either an NPN or PNP input OMRON Digital Controllers Manual.
Supports both external resetting and manual resetting OMRON Digital Controllers Manual.
Finger-protection terminal block cover prevents electrical shock and,
conforms to VDE0106, Part 100.
Safety standards: UL, CSA, EMC (EN 61326), CE Marking.
Control cycle: Yearly.
Number of outputs: 2 circuits.
Mounting method: Flush mounting.
Supply voltage: 24 VDC OMRON Digital Controllers Manual.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speeedier setting H5S-YB4-X User's Manual.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank functioon allows program switching by an external input H5S-YB4-X Manual.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series.