Product model: K3HB-HTA-BCD1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
File size: 2.28MB
Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-HTA-BCD1 User's Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-HTA-BCD1
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-HTA-BCD1 User's Manual. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-HTA-BCD1 User's Manual.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply volttage: AC100 ~ 240V K3HB-HTA-BCD1 Manual.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
Externall event input can be applied to a variety of measurement and identification situations K3HB-HTA-BCD1 Manual.
Series of DeviceNet type.
The depth (panel below) is only 95mm
Related products
OMRON
Temperature panel
K3HB-HTA-T11 AC100-240
OMRON Temperature panel K3HB-HTA-T11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC100-240
OMRON Temperature panel K3HB-HTA-L1AT11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L1AT11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-L2AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L2AT11 AC/DC24
Type of input: platinum resistance / thermoco