Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load) KM50-E1-FLK Manual.
Output relay can be switched between normally open and normally closed
KM50-E1-FLK
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with KM50-E1-FLK Manual.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution KM50-E1-FLK Manual.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviApplicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC OMRON AC SERVOMOTORS/SERVO DRIVES Manual.
Power supply voltage (shared): 100 to 240 VAC OMRON AC SERVOMOTORS/SERVO DRIVES Manual.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power OMRON AC SERVOMOTORS/SERVO DRIVES Manual.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power. KM50-E1-FLK User's Manual. )
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss KM50-E1-FLK Manual.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.