Product model: A0J2-62DA
Name: D/A Converter Unit
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 1.21MB
AC input points: 32 points.
Input voltage and current: AC100 ~ 10mA, 120V.
Response time: 35ms.
16 point /1 a public side.
Bidirectional thyristor output points: 24 points.
Output voltage and current: AC100 ~ 240V, 0.6A/1 point, 2.4A/1 public end.
Response time: 0.5Hz1ms.
8 point /1 a public end, 4 point /1 a public end MITSUBISHI D/A Converter Unit User's Manual.
36 point terminal table * 2.
Number of stations: 8 stops A0J2-62DA
Compact remote I/O unit.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system MITSUBISHI D/A Converter Unit User's Manual.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved MITSUBISHI D/A Converter Unit User's Manual.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc A0J2-62DA User's Manual. .
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses A0J2-62DA User's Manual.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc A0J2-62DA User's Manual. ,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the functionn of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system A0J2-62DA Manual .
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information MITSUBISHI D/A Converter Unit User's Manual.
Related products
MITSUBISHI
Bidirectional thyristor output module
A0J2-E24S
MITSUBISHI Bidirectional thyristor output module A0J2-E24S
Output points: 24 points. Voltage: AC100 24
MITSUBISHI
DC input module
A0J2-E32D
MITSUBISHI DC input module A0J2-E32D
Input points: 32 points. Voltage: DC12/24V. C
MITSUBISHI
CPU unit
A0J2HCPUR21
MITSUBISHI CPU unit A0J2HCPUR21
Input and output points: 480 points Input / o