LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> A2SHCPU-S1  Manual MITSUBISHI A2SHCPU-S1  Dedicated Instructions Programming Manual

A2SHCPU-S1  Manual MITSUBISHI A2SHCPU-S1  Dedicated Instructions Programming Manual

Product model: A2SHCPU-S1 
Name: CPU
Brand: MITSUBISHI
Sort: Dedicated Instructions Programming Manual
File language: English
File size: 4.50MB
Output points: 32 points.
Voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
38 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor MITSUBISHI A2SHCPU-S1  Programming Manual A2SHCPU-S1 
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc MITSUBISHI A2SHCPU-S1  Programming Manual. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI A2SHCPU-S1  Programming Manual.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Cable length: 0.5 meters.
For the GOT and the PC card interface unit (A1SD59J-MIF) connection.
For FXCPU expansion board FX2N-422-B, FX1N-422-BD and GOT connection. Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC12/24.
Input current: 3/7mA.
Output type: transistor drain type.
Output points: 32 points.
Common public end points: 32.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signaals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal A2SHCPU-S1  Manual .
So the standard telecommunication number, the conversiion between the number of operations to use a variety of computing A2SHCPU-S1  Manual .
This requires the resolution of the analog unit and the standard electrical signal.
Related products
MITSUBISHI
CPU component
A2SHCPU-S1
MITSUBISHI CPU component A2SHCPU-S1
I/O control method: refresh mode or direct mo