LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> A68B-UL Manual MITSUBISHI A68B-UL User's Manual

A68B-UL Manual MITSUBISHI A68B-UL User's Manual

Product model: A68B-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.41MB
Output points: 8 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 8A/1 common end.
Output response time: 12ms.
8 point /1 a public side.
Output form: relay output.
24 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered MITSUBISHI A68B-UL User's Manual.
It can avoid the control logic confusion caused by illegal operations A68B-UL
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc MITSUBISHI A68B-UL User's Manual. .
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI A68B-UL User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Number of channels: 2 channels.
Sensing methods and temperature range: R, K, J, T, S, B, E, N, U, L, PL, II,, Wre5-26,,, and.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC224V/0 A68B-UL Manual . 5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A68B-UL Manual .
Related products
MITSUBISHI
AD conversion module
A68AD
MITSUBISHI AD conversion module A68AD
8 channels. Input: DC-10 10V, DC4 20mA. O
MITSUBISHI
Analog input module
A68ADN
MITSUBISHI Analog input module A68ADN
8 channels. Input: DC-10 10V, -20 20mA. O
MITSUBISHI
Extended bottom plate
A68B
MITSUBISHI Extended bottom plate A68B
8 slots. To install the power supply. For QnA
MITSUBISHI
Analog output module
A68DAI-S1
MITSUBISHI Analog output module A68DAI-S1
8 channels. Input: DC0 20mA. Output resolu