Product model: AJ35TB1-16AR
Name: I/O MODULE
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 6.99MB
Axis of control: 1.
A1SD75 series components show the MITSUBISHI in the manufacture and design of CNC, frequency converter,
Integrated technical experience in servo system and PLC.
These components have a wealth of features that are sufficient to meet the highest requirements in the application of positioning control MITSUBISHI I/O MODULE User's Manual.
Up to 3 axis linkage operation,
In low cost motion control applications, this component can be used to control the operation of a multi - to 3 axis, which can be used to account for only one slot AJ35TB1-16AR Input points: 32 points.
Input voltage: AC100 ~ 120V.
Current: 6mA.
Response time: 30ms.
16 points / a common end.
50 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI I/O MODULE User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive MITSUBISHI I/O MODULE User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ35TB1-16AR User's Manual.
Each scanning process AJ35TB1-16AR User's Manual. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read AJ35TB1-16AR User's Manual.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image regisster are changed with the change of the execution of the program AJ35TB1-16AR Manual .
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling MITSUBISHI I/O MODULE User's Manual.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
Related products
MITSUBISHI
AC input / relay output module
AJ35TB1-16AR
MITSUBISHI AC input / relay output module AJ35TB1-16AR
AC input points: 8 points. Input voltage and
MITSUBISHI
Transistor output module
AJ35TB2-16T
MITSUBISHI Transistor output module
 AJ35TB2-16T
Output points: 16 points. Output voltage and
MITSUBISHI
DC input module
AJ35TB2-8D
MITSUBISHI DC input module AJ35TB2-8D
DC input points: 8 points. Input voltage and
MITSUBISHI
Relay output module
AJ35TB1A-8R
MITSUBISHI Relay output module
 AJ35TB1A-8R
Output points: 8 points. Output voltage and c