AJ71AP21 Manual MITSUBISHI Data Link Unit AJ71AP21 User's Manual

Product model: AJ71AP21
Name: Data Link Unit
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.76MB
Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side MITSUBISHI Data Link Unit User's Manual.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control AJ71AP21
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control MITSUBISHI Data Link Unit User's Manual.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc MITSUBISHI Data Link Unit User's Manual. .
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal AJ71AP21 User's Manual AJ71AP21 User's Manual.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal. Type of input: DC leakage.
Input points: 64 points AJ71AP21 User's Manual.
Input voltage: DC24.
Input current: 5mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and coomplex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced MITSUBISHI Data Link Unit User's Manual AJ71AP21 Manual .
Related products
MITSUBISHI
SI/QSI fiber optic cable module
AJ71QLP21S
MITSUBISHI SI/QSI fiber optic cable module AJ71QLP21S
SI/QSI/H-PCF/ wide range H-PCF fier optic ca
MITSUBISHI
ME-NET module
AJ71ME81
MITSUBISHI ME-NET module AJ71ME81
ME-NET interface unit. According to the contr
MITSUBISHI
ID system module
AJ71ID2-R4
MITSUBISHI ID system module AJ71ID2-R4
Bus connection. Program 2 channel connection.