Product model: CL1X2-D1D3S
Name: CC-Link/LT Remote I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.25MB
No introductionOutput type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting MITSUBISHI CL1X2-D1D3S User's Manual.
3 wire sensor input CL1X2-D1D3S Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector MITSUBISHI CL1X2-D1D3S User's Manual.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Output type: transistor output, drain type.
Output points: 2 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire MITSUBISHI CL1X2-D1D3S User's Manual.
Cable type.
Minimum size of industry.
Can be like a cable, placed in the online slot.
The communication cable and the external equipment connecting cable is a type, and the wiring is simple.
Communication side, input and output side with cable (50cm). Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reducce the cost and set space CL1X2-D1D3S Manual. No introductionVoltage and current output module.
Number of channels: 2 channels.
Occupied station number: 16 point pattern occupies 4 stations.
Screw terminal table type.
Input output points can be saveed by using different input and output points based on the final channel that allows the conversion CL1X2-D1D3S Manual.
Special flat cable directly mounted to the module.