Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 2A.
Ultra thin power supply.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value Q06PHCPU Strctured Programming Manual.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action
Q06PHCPU
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q06PHCPU Strctured Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q06PHCPU Strctured Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand MITSUBISHI Q06PHCPU Manual. Three-phase 3 wire type.
Measuring circuit number: 4 circuits MITSUBISHI Q06PHCPU Manual.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information MITSUBISHI Q06PHCPU Manual.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circcuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q06PHCPU Special Instructions.
For example, a module ccan be used to measure other loads from the control panel trunk Q06PHCPU Strctured Programming Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.