Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used Q12PRHCPU Strctured Programming Manual.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection
Q12PRHCPU
Easy connection through the hub CPU.
By using an Ethernet hub, programming tools and multiple CPU can be connected simultaneously.
Through the programming tool can be searched and displayed in the list has been connected to the CPU Q12PRHCPU Strctured Programming Manual.
Therefore, even if the IP CPU address is unknown, just choose from this list, you can easily connect.
Seamless communication without network level constraints.
With the latest high-speed, large capacity IE CC-Link controller network and IE CC-Link field network,
Corresponding to the increasing amount of information.
Together with previous MELSECNET/H, Ethernet and CC-Link,
These networks can be across the network type or level of differences, to achieve seamless communication Q12PRHCPU Strctured Programming Manual.
Programmable logic controller on the network through the programming tool of the Ethernet connection,
Monitoring and programming MITSUBISHI Q12PRHCPU Manual. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,) MITSUBISHI Q12PRHCPU Manual.
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI Q12PRHCPU Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiplee loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q12PRHCPU Application Functions.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q12PRHCPU Strctured Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.