Max input / output points: 20 points.
Power supply voltage: DC24V.
Input points: 12 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption (W): 20.
Weight (kg):0.4.
Size (WxHxD) mm:75x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time FX0N-232ADP Manual.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control
FX0N-232ADP
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FX0N-232ADP Manual.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FX0N-232ADP Manual. Total points: 40 points.
Input points: 24 points.
Output points: 16 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 130*75*90.
FX1N series is a very powerful micro PLC,
Can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board MITSUBISHI FX0N-232ADP User's Manual.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect MITSUBISHI FX0N-232ADP User's Manual. MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 3.7KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
Thee sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, ffundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power MITSUBISHI FX0N-232ADP User's Manual FX0N-232ADP Manual FX0N-232ADP .