Product model: D4N-2D72R
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC OMRON pull-reset safety limit switch INSTRUCTION sheet D4N-2D72R
Conduit opening: G1/2.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum OMRON pull-reset safety limit switch INSTRUCTION sheet.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Short/disconnection detection: Supported.
Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector OMRON pull-reset safety limit switch INSTRUCTION sheet.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work D4N-2D72R INSTRUCTION sheet.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Release Key Type: Special (resin) D4N-2D72R INSTRUCTION sheet.
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ D4N-2D72R INSTRUCTION sheet.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the hhead D4N-2D72R Manual.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON pull-reset safety limit switch INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-2ERE
OMRON Safety Limit Switch D4N-2ERE
Actuator: Fork lever lock right operation.
OMRON
Pull-reset Safety Limit Switch
D4N-9A20R
OMRON Pull-reset Safety Limit Switch D4N-9A20R
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-6120
OMRON Safety Limit Switch D4N-6120
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-4ELE
OMRON Safety Limit Switch D4N-4ELE
Actuator: Fork lever lock left operation.