LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> D4N-6A2G Manual OMRON D4N-6A2G INSTRUCTION sheet

D4N-6A2G Manual OMRON D4N-6A2G INSTRUCTION sheet

Product model: D4N-6A2G
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models OMRON D4N-6A2G INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4N-6A2G
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers OMRON D4N-6A2G INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release OMRON D4N-6A2G INSTRUCTION sheet.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Type of drive rod: one-way action roller type (vertical motion).
Conduit size: single catheter type, M20.
Built in switch structure: slow mmotion (1NC/1NO) D4N-6A2G Manual.
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forcedd open action structure D4N-6A2G Manual.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-2D2GR
OMRON Pull-reset Safety Limit Switch D4N-2D2GR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-2C26
OMRON Safety Limit Switch D4N-2C26
Actuator: Roller lever metal lever, earing
OMRON
Safety Limit Switch
D4N-6F62
OMRON Safety Limit Switch D4N-6F62
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-6172
OMRON Safety Limit Switch D4N-6172
Actuator: One-way roller arm lever vertical