Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms OMRON safety limit switch INSTRUCTION sheet.
(Slow-action models with MBB contacts are available
D4N-8D31)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release key type: Trapped key *1 OMRON safety limit switch INSTRUCTION sheet.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads OMRON safety limit switch INSTRUCTION sheet.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas D4N-8D31 INSTRUCTION sheet.
IP67 degree of protection. Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector D4N-8D31 INSTRUCTION sheet.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating) D4N-8D31 INSTRUCTION sheet.
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Type: Welding / wire type, M3 screw mounting.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, under the lead.
Contact specifications: 1c.
The minimum siize of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4N-8D31 Manual.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 OMRON safety limit switch INSTRUCTION sheet. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.