LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> D4NS-7CF Manual OMRON D4NS-7CF INSTRUCTION sheet

D4NS-7CF Manual OMRON D4NS-7CF INSTRUCTION sheet

Product model: D4NS-7CF
Name: safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.56MB
Actuator: Roller plunger.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available OMRON D4NS-7CF INSTRUCTION sheet. )
M12-connector models are also available, saving on labor and,
simplifying replacement D4NS-7CF
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: 0.1 A.
Actuator: Hinge roller lever OMRON D4NS-7CF INSTRUCTION sheet.
Terminals: Solder terminals.
Contact form: SPDT.
Sealed Miniature Basic.
Switch Conforms to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing, making.
this switch ideal for places subject to water spray.
or excessive dust.
V-series internal mechanism assures high.
precision and durability. The mounting is the,
same as of the V models.
Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial,
equipment, which require high environmental resistance OMRON D4NS-7CF INSTRUCTION sheet. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
SSelectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4NS-7CF Manual.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads D4NS-7CF Manual.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.
Related products
OMRON
Safety-door Switch
D4NS-6EF
OMRON Safety-door Switch D4NS-6EF
Type: 2-Conduit. Contact configuration: Slow
OMRON
Safety-door Switch
D4NS-8DF
OMRON Safety-door Switch D4NS-8DF
Type: 2-Conduit. Contact configuration: Slow
OMRON
Safety-door Switch
D4NS-4BF-SJ
OMRON Safety-door Switch D4NS-4BF-SJ
Type: 1-Conduit High pull-force type. Cont
OMRON
Safety-door Switch
D4NS-1BF
OMRON Safety-door Switch D4NS-1BF
Type: 1-Conduit. Contact configuration: Slow