Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC OMRON guard lock safety-door switch INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement
D4SL-N4RDA-D
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Unique 18-mm-dia. Capacitive Touch.
Switch with Choice of Three Actuators is OMRON guard lock safety-door switch INSTRUCTION sheet.
Activated with Only a Very Slight.
Physical Contact.
Only a slight activation force is required, enabling detecting micro.
deflections, thin wires, or thin-plate conductors (e.g., steel or stainless).
Application possible for non-conductors by indirectly connecting to ground.
Instantaneous operation upon contact with extremely limited,
hysteresis for high-precision position detection OMRON guard lock safety-door switch INSTRUCTION sheet.
Diameter of only 18 mm with standard built-in amplifier, operation,
indicator, and sensitivity adjustment.
Conforms to IEC IP67 .
Freely replaceable antenna with screw mounting D4SL-N4RDA-D INSTRUCTION sheet.
Free attachment to enable changing the antenna shape according to the application. Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1 D4SL-N4RDA-D INSTRUCTION sheet.
Actuator: Crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N4RDA-D INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available onn standard models D4SL-N4RDA-D Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation OMRON guard lock safety-door switch INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)