Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black OMRON proximity sensor INSTRUCTION sheet.
Control output 1: output unit mode.
Control output 2: output unit mode
E2E-S04N02-CJ-C1
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON proximity sensor INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV OMRON proximity sensor INSTRUCTION sheet.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2E-S04N02-CJ-C1 INSTRUCTION sheet E2E-S04N02-CJ-C1 INSTRUCTION sheet.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 10 mm.
Connecting method (See note 1 E2E-S04N02-CJ-C1 INSTRUCTION sheet. ): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Item: Water-resistant models.
Connection method: Connector (M8).
RRatings and Specifications: Degree of protection: IP66 E2E-S04N02-CJ-C1 Manual.
Model: NPN output.
Simple and Affordable Fiber Amplifier Units.
Reasonable price.
Use the one-key one-function feature for quick,
easy operation.
GIGA RAY for the highest level of power in this class for,
stable detection even with sensing objects with low OMRON proximity sensor INSTRUCTION sheet.
reflection or large sensing objects.