LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> E2EM-X2C1-M1 Manual OMRON proximity switch E2EM-X2C1-M1 INSTRUCTION sheet

E2EM-X2C1-M1 Manual OMRON proximity switch E2EM-X2C1-M1 INSTRUCTION sheet

Product model: E2EM-X2C1-M1
Name: proximity switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 1.34MB
Type: Shielded.
Appearance: Screw, M10 × 22 mm.
Sensing distance: 2 mm.
Repeat accuracy: 2 μm.
Cable specification: With Protective Spiral Tube.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application OMRON proximity switch INSTRUCTION sheet. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads E2EM-X2C1-M1
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations OMRON proximity switch INSTRUCTION sheet.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision OMRON proximity switch INSTRUCTION sheet.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E2EM-X2C1-M1 INSTRUCTION sheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2EM-X2C1-M1 INSTRUCTION sheet. Control output: linear current output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V E2EM-X2C1-M1 INSTRUCTION sheet.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold seeparately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E2EM-X2C1-M1 Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete OMRON proximity switch INSTRUCTION sheet.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
Related products
OMRON
Long-distance Proximity Sensor
E2EM-X2C2 2M
OMRON Long-distance Proximity Sensor E2EM-X2C2 2M
Appearance: Shielded, M8. Sensing distance:
OMRON
Long-distance Proximity Sensor
E2EM-X4C2-M1
OMRON Long-distance Proximity Sensor E2EM-X4C2-M1
Appearance: Shielded, M12. Sensing distance:
OMRON
Long-distance Proximity Sensor
E2EM-X4C1-M1
OMRON Long-distance Proximity Sensor E2EM-X4C1-M1
Appearance: Shielded, M12. Sensing distance:
OMRON
Long-distance Proximity Sensor
E2EM-X15C1-M1
OMRON Long-distance Proximity Sensor E2EM-X15C1-M1
Appearance: Shielded, M30. Sensing distance: