Product model: E2FM-X10D1-M1TGJ-T
Name: proximity switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 1.48MB
High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: shield, M30.
Detection range: 10mm.
Output configuration: PNP.
Action mode: NC. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON proximity switch INSTRUCTION sheet.
Shell color: black E2FM-X10D1-M1TGJ-T
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON proximity switch INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors OMRON proximity switch INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) E2FM-X10D1-M1TGJ-T INSTRUCTION sheet.
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller E2FM-X10D1-M1TGJ-T INSTRUCTION sheet. Connecting method: Pre-wired (2 m).
Models: PNP output, E3X-HD41 2M.
Easy and optimum settings for anyone.
Smart Fiber Amplifier Unit with Long-term Stable Detection.
Equipped with Smart Tuning, which automatically configures the,
settings to their optimum values with the press of a single button E2FM-X10D1-M1TGJ-T INSTRUCTION sheet.
Highly usable design enables anyone to configure the settings easily.
Detects dirt, vibrations, and LED deterioration, and automatically,
compensates the incident level and the light intensity.
Unparalleled best-in-class power provides stable detections for low,
reflective workpieces and large workpieces (equipped with GIGA RAY II). Control output: relay output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold seeparately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E2FM-X10D1-M1TGJ-T Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete OMRON proximity switch INSTRUCTION sheet.