File size: 4.11MB
E32-M21 type: special beam type; region detection,
Specialty: multi point detection (4 probe),
Shape / detection distance (mm): 750; 610; 350 (140),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 2 (0.1),
Fiber element for meeting diversified needsThe Ultimate Fiber Amplifier for OMRON E2V-X8B1-M1TJ INSTRUCTION sheet.
Maximum Ease of Use and High.
Performance. Sensing range: 120 to 2,000 mm E2V-X8B1-M1TJ
Now, more advanced with a new mutual.
interference prevention function.
Long-distance detection of up to 6,000 mm supports a wide vari,
ety of applications.
The Sensor is not affected by the color or material of objects.
A setting plug with temperature compensation makes it easy to,
set the sensing range OMRON E2V-X8B1-M1TJ INSTRUCTION sheet.
Mutual interference prevention.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON E2V-X8B1-M1TJ INSTRUCTION sheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) maakes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2V-X8B1-M1TJ Manual.
Through the infrared port can be carried out from the frront of the communication E2V-X8B1-M1TJ Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Chip-immune Inductive Proximity Sensor
E2EZ-X4D1-M1TJ 0.3M
OMRON Chip-immune Inductive Proximity Sensor E2EZ-X4D1-M1TJ 0.3M
Appearance: Shielded, M18. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X15B1-M1TJ 0.3M
OMRON All Metals and Long-distance Types E2V-X15B1-M1TJ 0.3M
Appearance: Shielded, M30. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X15C1-M1TJ 0.3M
OMRON All Metals and Long-distance Types E2V-X15C1-M1TJ 0.3M
Appearance: Shielded, M30. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X4C1-M1TJ 0.3M
OMRON All Metals and Long-distance Types E2V-X4C1-M1TJ 0.3M
Appearance: Shielded, M12. Sensing distance: