Product model: E3S-AT61
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.24MB
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P OMRON E3S-AT61 Manual E3S-AT61
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 OMRON E3S-AT61 Manual. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON E3S-AT61 Manual.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further perrformance improvement E3S-AT61 INSTRUCTION sheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E3S-AT61 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT91
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT91
Sensing method: Through-eam Sensors. Appear
OMRON
Amplifier built-in type photoelectric switch
E3S-BT61
OMRON Amplifier built-in type photoelectric switch E3S-BT61
Small, easy to use. Detection mode: on the ra
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD68
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD68
Sensing method: Diffuse-reflective Sensors.
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD13
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD13
Sensing method: Diffuse-reflective Sensors.