LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> E3T-FL13R Manual OMRON E3T-FL13R INSTRUCTION sheet

E3T-FL13R Manual OMRON E3T-FL13R INSTRUCTION sheet

Product model: E3T-FL13R
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Appearance: Unshielded, M18.
Sensing distance: 14 mm.
Model: Operation mode, NC.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Size: 96 x 96mm OMRON E3T-FL13R INSTRUCTION sheet.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) E3T-FL13R
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output) OMRON E3T-FL13R INSTRUCTION sheet.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON E3T-FL13R INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermoo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3T-FL13R Manual.
Through the infrared port can be carried out from the frront of the communication E3T-FL13R Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Photoelectric Sensors
E3T-FD13
OMRON Photoelectric Sensors E3T-FD13
Sensing method: Diffuse-reflective. Connecti
OMRON
Photoelectric Sensors
E3T-SL11
OMRON Photoelectric Sensors E3T-SL11
Sensing method: Convergent-reflective. Conne
OMRON
Photoelectric Sensors
E3T-ST14
OMRON Photoelectric Sensors E3T-ST14
Sensing method: Through-eam. Connection met
OMRON
Photoelectric Sensors
E3T-ST21
OMRON Photoelectric Sensors E3T-ST21
Sensing method: Through-eam. Connection met