LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> E3T-SL14 Manual OMRON photoelectric sensors E3T-SL14 INSTRUCTION sheet

E3T-SL14 Manual OMRON photoelectric sensors E3T-SL14 INSTRUCTION sheet

Product model: E3T-SL14
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Size: M30, Shielded.
Sensing distance: 15.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 66 (86).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor OMRON photoelectric sensors INSTRUCTION sheet.
Problems such as the collision of workpieces are eliminated E3T-SL14
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling OMRON photoelectric sensors INSTRUCTION sheet.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON photoelectric sensors INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E3T-SL14 INSTRUCTION sheet.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP E3T-SL14 INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3T-SL14 INSTRUCTION sheet.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous modeels with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3T-SL14 Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON photoelectric sensors INSTRUCTION sheet.
Related products
OMRON
Photoelectric Sensors
E3T-ST12
OMRON Photoelectric Sensors E3T-ST12
Sensing method: Through-eam. Connection met
OMRON
Photoelectric Sensors
E3T-SL21
OMRON Photoelectric Sensors E3T-SL21
Sensing method: Convergent-reflective. Conne
OMRON
Photoelectric Sensors
E3T-ST11
OMRON Photoelectric Sensors E3T-ST11
Sensing method: Through-eam. Connection met