Product model: E3T-ST34R
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON photoelectric sensors INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers E3T-ST34R
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Control output 1: current.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 4 OMRON photoelectric sensors INSTRUCTION sheet.
Communication: -.
Disconnection detection: 1.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set OMRON photoelectric sensors INSTRUCTION sheet.
It can be easily set by CX-Thermo (sold separately) E3T-ST34R INSTRUCTION sheet.
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications E3T-ST34R INSTRUCTION sheet.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Size: 96 x 96mm.
Control output 1: relay output E3T-ST34R INSTRUCTION sheet.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable foor a wide range of applications E3T-ST34R Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication OMRON photoelectric sensors INSTRUCTION sheet.
A new type of proportional control allows you to control the valve.
Related products
OMRON
Photoelectric Sensors
E3T-ST21
OMRON Photoelectric Sensors E3T-ST21
Sensing method: Through-eam. Connection met
OMRON
Photoelectric Sensors
E3T-ST23
OMRON Photoelectric Sensors E3T-ST23
Sensing method: Through-eam. Connection met