Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: - OMRON digital controller INSTRUCTION Manual.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E5AC-CX4ASM-005
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance OMRON digital controller INSTRUCTION Manual.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set OMRON digital controller INSTRUCTION Manual.
It can be easily set by CS-Thermo (sold separately). The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5AC-CX4ASM-005 INSTRUCTION Manual.
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5AC-CX4ASM-005 INSTRUCTION Manual.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5AC-CX4ASM-005 INSTRUCTION Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increasse the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5AC-CX4ASM-005 Manual. Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connecttion method: Pre-wired OMRON digital controller INSTRUCTION Manual.
Sensing distance: 700 mm.
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors.