Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON digital controller INSTRUCTION Manual.
Event entry point: 2
E5AN-R3HBTD-N
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved OMRON digital controller INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON digital controller INSTRUCTION Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault E5AN-R3HBTD-N INSTRUCTION Manual.
Position ratio type. High performance price ratio standard type proximity sensor E5AN-R3HBTD-N INSTRUCTION Manual.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: there.
Shape: non shield, M12.
Detection range: 8mm.
Action mode: NC. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC E5AN-R3HBTD-N INSTRUCTION Manual.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, No; Mounting option units, No.
Previous model: E5AZ-R3 E5AZ-A3 + E53-AZR.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer ouutput provided for easy output to recorders E5AN-R3HBTD-N Manual.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications OMRON digital controller INSTRUCTION Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.