Appearance: Shielded, M12.
Sensing distance: 2 mm.
Output: NPN.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Power supply voltage: 5 VDC.
Output configuration: Line-driver output.
Resolution (pulses/rotation): 10, 20, 30, 40, 50, 60, 100, 200, 300,
360, 400, 500, 600; 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 OMRON digital controller INSTRUCTION Manual
E5EN-R3HHT-N
General-purpose Encoder with.
External Diameter of 50 mm.
Incremental model.
External diameter of 50 mm.
Resolution of up to 2,000 ppr.
IP64 (improved oil-proof construction with sealed bearings).
Side or back connections are possible. Pre-wired Models with cable,
connected at an angle. High performance price ratio standard type proximity sensor OMRON digital controller INSTRUCTION Manual.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: non shield, M30.
Detection range: 18mm.
Output configuration: NPN.
Action mode: NC. Appearance: M5.
Sensing distance: 1.2 mm.
Connecting method: M8 Pre-wired Connector Models .
Cable specifications: --.
Operation mode: NO.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output OMRON digital controller INSTRUCTION Manual.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available E5EN-R3HHT-N INSTRUCTION Manual.
High-speed response frequency stably detects moving,
objects: 5 kHz max E5EN-R3HHT-N INSTRUCTION Manual.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables E5EN-R3HHT-N INSTRUCTION Manual. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatiic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EN-R3HHT-N Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output OMRON digital controller INSTRUCTION Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.