Power: 22kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor MITSUBISHI INVERTER Instruction manual. (the IP55 series has a built-in DC reactor
FR-F720P-1.5K)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Enter 32 points or 32 points;
Divided into 16 points, 16 points out of the output.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection MITSUBISHI INVERTER Instruction manual. Connecting cable for handheld RH GOT and PLC.
Cable length: 10 meters.
Application: RS-422 connection and RS-232C connection. Total input and output points: 40 points.
Input points: 24 points MITSUBISHI INVERTER Instruction manual.
Output points: 16 points.
Output type: relay output.
Power supply voltage: AC100-240V.
Input signal voltage: DC24V.
8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0 FR-F720P-1.5K Instruction manual. 08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules FR-F720P-1.5K Instruction manual.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable FR-F720P-1.5K Instruction manual.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FR-F720P-1.5K Manual .
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program MITSUBISHI INVERTER Instruction manual.