Product model: FX1N-24MT-ES/UL
Name: PLC
Brand: MITSUBISHI
Sort: HARDWARE MANUAL
File language: English
File size: 2.00MB
Input and output points: 10 points.
Power supply: DC24V.
Input points: 6 points.
Output points: 4 points.
Output form: relay output.
Power consumption: 6W.
Weight: 0.22KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features.
Special adaptor and function expansion board can be installed and used FX3 series MITSUBISHI PLC HARDWARE MANUAL FX1N-24MT-ES/UL
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models MITSUBISHI PLC HARDWARE MANUAL.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. Power: 280kw.
Voltage: 400V.
Purpose: high frequency braking resistor MITSUBISHI PLC HARDWARE MANUAL.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available FX1N-24MT-ES/UL HARDWARE MANUAL.
Please select according to the required braking torque. Analog input points: 4 points (thermocouple, PT, constant voltage input) FX1N-24MT-ES/UL HARDWARE MANUAL.
Output points: transistor output 4 points, 4 point CT input.
Weight: 0.4KG.
Temperature sensor with 4CH input control output,
Double position control, standard PID control,
Heating and cooling PID control, cascade control.
By using the combination of the analog output module,
PID control of voltage or current can be realized FX1N-24MT-ES/UL HARDWARE MANUAL.
New with cascade control. Through the master / slave station of the 2 controllers,
According to the temperature change caused by external disturbance, the temperature can be adjusted quickly.
Can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basiccally can not be used FX1N-24MT-ES/UL Manual. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced MITSUBISHI PLC HARDWARE MANUAL.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Related products
MITSUBISHI
PLC
FX1S-10MT-ES/UL
MITSUBISHI PLC FX1S-10MT-ES/UL
Max input / output points: 10 points. Supply
MITSUBISHI
PLC
FX1N-14MT-ES/UL
MITSUBISHI PLC FX1N-14MT-ES/UL
Max input / output points: 14 points. Supply
MITSUBISHI
PLC
FX2N-48MT-ES/UL
MITSUBISHI PLC FX2N-48MT-ES/UL
Max input / output points: 48 points. Supply
MITSUBISHI
PLC
FX1N-24MR-001
MITSUBISHI PLC FX1N-24MR-001
Total points: 24 points. Input points: 14 poi